Pioneer Mini Split 27,000 BTU 2 Zone Ductless Air Conditioner and Heat Pump with 50 ft. Kits - WYT030GLHI22M3-18W-9W-50
Meet the Pioneer Diamante Mini Split System to cool and heat two different rooms. You'll be sent: 27,000 BTU Multi-Zone Condenser, one 9,000 BTU Wall Mounted Air Handler, one 18,000 BTU Wall Mounted Air Handler, two Remotes, and two 50 ft. Installation Kits.
System Includes
Condenser
- Energy Efficient. This 3 Zone condenser, when paired with select Pioneer air handlers, is capable of producing up to an impressive 22 SEER efficiency rating.
- Works In All Environments. The ability to heat even when temperatures drop to -4°F and cool up to 122°F
- Iron-Clad Warranty. For added peace of mind, this condenser comes with a 5 Year Warranty. Simply register within 90 days and you'll be covered!
Air Handler, 9K BTU, Quantity 1
-
Large Coverage Area. Handler covers an area of up to 350 sq. ft
- Versatile. Incredibly versatile and equipped with multiple operating modes, which include COOL, HEAT, TURBO, ECO and SLEEP.
-
Convenient Installation. With its light and compact design, it can be installed easily to most interior walls with the included mounting plate.
Air Handler, 18K BTU, Quantity 1
-
Large Coverage Area. Handler covers an area of up to 650 sq. ft
- Versatile. Incredibly versatile and equipped with multiple operating modes, which include COOL, HEAT, TURBO, ECO and SLEEP.
-
Convenient Installation. With its light and compact design, it can be installed easily to most interior walls with the included mounting plate.
Line Set 50 ft., Quantity 1
- This 50 ft. copper line set connects the Pioneer Diamante Series Condenser to the 9K and 12K Air Handlers
Line Set 50 ft., Quantity 1
- This 50 ft. copper line set connects the Pioneer Diamante Series Condenser to the 18K Air Handlers.
What's Not Included and Required for Installation
- Electrical Requirements, such as Disconnect Box or Electrical Whip
- Vacuum Pump or Vacuum Set (alternatively, you can use the Pioneer Flush Kit)
Specifications
Condenser |
Product Dimensions |
35 1/8"W x 14"D x 31 3/8"H |
Cooling Capacity |
24,000 BTU |
Heating Capacity |
26,000 BTU |
Zone Capacity |
3 |
SEER |
22 |
Outdoor Ambient Range (Cool) |
5°F~122°F |
Outdoor Ambient Range (Heat) |
-4°F~86F |
Voltage |
Requires a minimum of 208V-230V/60HZ/15A (double-pole) (please check your home meets this electrical requirement prior to purchase) |
Air Handler 9K |
Product Dimensions |
32 1/4"W x 7" 5/8"D x 12"H |
Mount Type |
Wall |
Cooling Capacity |
9,000 BTU |
Heating Capacity |
9,500 BTU |
Square Footage Coverage |
350 Square Feet |
Air Handler 18K |
Product Dimensions |
43 3/8"W x 8 3/4"D x 13 1/8"H |
Mount Type |
Wall |
Cooling Capacity |
18,000 BTU |
Heating Capacity |
18,000 BTU |
Square Footage Coverage |
650 Square Feet |
Line Set |
Length |
50 Feet |
INSTALLATION & GUIDES
What Our Experts Think
-
27,000 BTU Capacity: Ideal for large spaces or multi-room setups, providing efficient heating and cooling for multiple zones with optimal comfort.
-
2 Zone Capability: Independently control the temperature in two different rooms or areas, perfect for homes or offices with multiple rooms requiring separate climate control.
-
Inverter Technology: Offers precise temperature regulation, quieter operation, and enhanced energy savings for consistent, reliable comfort.
-
Ductless Design: No need for complex ductwork, making installation simpler and more flexible for a variety of spaces.
-
50 ft. Line Sets Included: Comes with a 50 ft. pre-charged refrigerant line set, giving flexibility for installation and accommodating larger areas or more distant units.
-
Heat Pump Functionality: Dual functionality for both heating and cooling, making it an ideal solution for year-round climate control in diverse weather conditions.
-
Quiet Operation: Designed to operate quietly, ensuring a comfortable environment without disrupting daily activities.
Q&A
Q: What is the cooling capacity of the Pioneer 27,000 BTU 2 Zone Mini-Split system?
A: This system provides 27,000 BTU of cooling power, making it ideal for larger spaces or multiple rooms up to 1,100 sq. ft. combined.
Q: Does the Pioneer 27,000 BTU 2 Zone Mini-Split system provide both cooling and heating?
A: Yes, it functions as both an air conditioner and a heat pump, offering year-round comfort with efficient cooling and heating.
Q: What is the SEER rating of the Pioneer 27,000 BTU 2 Zone Mini-Split system?
A: It features a 22 SEER rating, ensuring high energy efficiency to lower your electricity costs.
Q: What is included in the installation kit for the Pioneer 27,000 BTU 2 Zone Mini-Split system?
A: This system comes with 50 ft. of line sets, allowing flexibility in installation and making it suitable for larger or more complex layouts.
Q: What are the key features of the Pioneer 27,000 BTU 2 Zone Mini-Split system?
A: This system includes inverter technology for improved efficiency, quiet operation, advanced air filtration, and dual-zone capability for customized climate control.
Q: Is the Pioneer 27,000 BTU 2 Zone Mini-Split system easy to install?
A: Yes, it comes with a 50 ft. line set for easy installation, making it a flexible solution for various room configurations.
Maintenance Tips
-
Clean or Replace Filters: Wash the air filters every 2-4 weeks to maintain airflow and system efficiency. Replace them annually or if they become excessively dirty or damaged.
-
Clean the Coils: Clean the evaporator and condenser coils at least once a year to remove dust and debris, which can hinder performance.
-
Inspect the Drain Line: Regularly check the condensate drain line for clogs. Clear any blockages to prevent water leaks and mold growth in the system.
-
Monitor Refrigerant Levels: Ensure the refrigerant levels are sufficient for efficient heating and cooling. If you notice decreased performance, consult a professional technician for inspection and recharging.
-
Clear Airflow Paths: Keep both the indoor and outdoor units free from obstructions like furniture, leaves, or debris to ensure optimal airflow and reduce strain on the system.
-
Check for Proper Distribution: Ensure both zones are receiving balanced airflow and cooling/heating. If one zone is underperforming, check for any blockages or malfunctioning components.
-
Schedule Annual Professional Maintenance: Have a technician inspect the system annually, including checking refrigerant levels, cleaning coils, and ensuring the system runs at peak efficiency.