Get In Touch
Get In Touch +1 (888) 575-2099
Dial +1 (888) 575-2099
grab it before it's gone.
As low as possible.
Never used.
$200.00
$70.00
$100.00
$30.00
$300.00
$100.00
Products added to cart!
At Pioneer Mini Split, we offer variable capacity ductless wall-mounted mini split systems, available with different efficiency ratings and in a variety of capacities for simple installation and great single-zone comfort. Our ductless mini split wall-mounted air conditioners and heat pumps come with a convenient remote controller conveys cooling, heating, dehumidification, and ventilation requests to the wall-mount ductless mini split system, while automatic air-sweeping louvers, automatically varying air flow, and capacity adjustments keep the zone at the ultimate comfort level. This results in minimal electrical consumption for a more efficient ductless wall air conditioner and heating system. Check out our selection of wall-mounted heating and cooling units today!
Optional
Performance Data | |
---|---|
Power Supply | 208~230V, 60Hz, 1Ph |
Cooling Rated Capacity | 12,000 BTU/h |
Cooling Capacity Range | 3,536~12,931 BTU/h |
Cooling SEER | 22.0 BTU/w |
Cooling EER | 12.5 BTU/w |
SEER2 | 23.1 |
Heating Rated Capacity | 12,000 BTU/h |
Heating Capacity Range | 4,520~17,305 BTU/h |
Heating HSPF | 10.8 BTU/w |
Heating C.O.P. | 3.5 W/W |
Refrigerant Type | R410a |
Suitable Area | 200~450 Sq.F |
Warranty | 5 years parts and compressor warranty |
Condenser | |
Sound Level | 53.5 dB(A) |
Breaker Needed | 15A (double-pole) |
Net Dimensions (WDH) | 30 1/8"W x 11 7/8" D x 21 7/8" H |
Carton Dimensions (WDH) | 34 7/8" W x 13 1/4" D x 24" H |
Net / Gross Weight | 63.7 / 69 Lbs |
Cool Mode - Outdoor Operating Temperature Range | 5° to 122°F |
Heat Mode - Outdoor Operating Temperature Range | -13° to 75°F |
Air Handler | |
Air Flow (Hi/Med/Lo) | 306 / 212 / 147 CFM |
Sound Level (Hi/Med/Lo) | 37.5 / 30.0 / 21.5 dB(A) |
Net Dimensions (WDH) | 31 1/2" W x 7 3/8" D x 11 5/8" H |
Carton Dimensions (WDH) | 34 1/2" W x 11 1/4" D x 15" H |
Net / Gross Weight | 19 / 24 Lbs |
Q: What is the Pioneer 12,000 BTU 22 SEER Ductless Mini-Split Inverter++ Air Conditioner Heat Pump System?
A: This high-efficiency mini-split system offers both cooling and heating with a 22 SEER rating. Featuring Inverter++ technology, it ensures quiet, energy-efficient operation and precise temperature control. It includes 10 ft. line sets for easy installation.
Q: How does Inverter++ technology enhance the system's performance?
A: Inverter++ technology adjusts the compressor speed to match real-time temperature demands, resulting in better energy efficiency, quieter operation, and more consistent comfort.
Q: What size room can this system cover?
A: This system is ideal for cooling and heating rooms up to 450 sq. ft.
Q: Is it suitable for residential use?
A: Yes, this system is perfect for residential settings, offering reliable comfort with minimal noise and energy savings.
Q: Does it require professional installation?
A: While the unit includes 10 ft. line sets for convenience, professional installation is recommended to ensure optimal performance and longevity.
Clean the Air Filters Regularly: Air filters should be cleaned every 1-2 months to prevent the buildup of dust and dirt, which can reduce airflow and efficiency. Use a vacuum or wash the filters with mild soap and warm water, allowing them to dry completely before reinstalling.
Check for Ice Build-Up: Inspect the evaporator coil and air handler for ice during operation. Ice buildup can be a sign of restricted airflow, low refrigerant, or a malfunctioning component. If you notice ice, switch the unit off and contact a technician for a thorough inspection.
Clear the Drain Line: Ensure the condensate drain line is free from clogs, as a blocked drain can cause water damage or mold growth. Clear the line periodically to allow water to flow freely and keep your system working efficiently.
Clean the Coils and Fins: Dust and dirt can accumulate on both the evaporator and condenser coils, affecting heat exchange efficiency. Clean the coils and fins with a soft brush or compressed air every few months to maintain proper airflow and efficiency.
Check Refrigerant Levels: Low refrigerant can lead to reduced cooling or heating performance and may cause further damage to the compressor. Have a licensed technician check the refrigerant level regularly to ensure the system is operating at peak efficiency.
Inspect the Outdoor Unit: Keep the outdoor unit free from debris such as leaves, twigs, and dirt. Make sure there's at least 2-3 feet of clearance around the unit to ensure proper airflow and prevent overheating.
Ensure Proper Insulation: Check the insulation on refrigerant lines for any signs of wear or damage. Proper insulation reduces energy loss and improves the efficiency of your system.
Inspect the System's Performance: Periodically check the system's overall performance. If you notice decreased airflow, unusual noises, or inconsistent temperatures, it's important to consult a technician to address any potential issues before they worsen.
Schedule Annual Professional Maintenance: To ensure long-term reliability and optimal performance, schedule an annual professional inspection and maintenance. A technician will clean internal components, check refrigerant levels, and perform any necessary repairs.
Thanks for subscribing!
This email has been registered!